Oil-Water Separators

SmartSep Oil-Water Separators

Saturation Indicator

Green indicator signals the need to replace the fully saturated polypropylene pre-filter

External Drain Valve

Red Smart Service Overflow indicator notifies the need to reduce the amount of condensate flow into the device

Test Outlet

Helps verify and monitor filtration performance between service intervals

Get the most out of your system with the device that provides optimal filtration and separation to meet and exceed environmental regulations across the globe.

Compact and efficient, the Walker Filtration SmartSep Oil-Water Separator Series is engineered to ensure the highest levels of condensate purity through a multi-stage filtration system.

Its 4,000-hour service interval and Smart Service Overflow Indicator helps eliminate costly external service testing and overall maintenance frequency.

Exclusive to SmartSep, the Organoclay cartridges allow your system to stay ahead of current and future environmental regulations by eliminating stable emulsions and heavy oil traces for the highest level of condensate purification.

  • Cost Saving Extended service periods and environmental compliance helps save money on frequent upkeep and costly violations
  • Simple Service Sensory overflow indicator, external test valve, and easy to swap polypropylene bags and cartridges save time on overall product maintenance
  • Comprehensive Range Various sizes and a compact design allow for the perfect fit for your compressed air system
  • Space Saver Manifold inlets for multiple condensate lines and wall brackets for small systems save space in compressor rooms

SSEP0032 and SSEP0066

Single-usage units ideal for space-saving and cost-efficiency

SSEP0132 to SSEP1655

Uses dual-stage filtration technology to remove a range of contaminants

SSEP3311

Utilizes multi-stage filtration for heavier condensate flows and further purification

SSEP6621

Comes with a flow divider to split condensate flow between two units

SSEP0032 and SSEP0066

Single-usage units ideal for space-saving and cost-efficiency

SSEP0132 to SSEP1655

Uses dual-stage filtration technology to remove a range of contaminants

SSEP3311

Utilizes multi-stage filtration for heavier condensate flows and further purification

SSEP6621

Comes with a flow divider to split condensate flow between two units

SSEP0032 and SSEP0066

Single-usage units ideal for space-saving and cost-efficiency

SSEP0132 to SSEP1655

Uses dual-stage filtration technology to remove a range of contaminants

SSEP3311

Utilizes multi-stage filtration for heavier condensate flows and further purification

SSEP6621

Comes with a flow divider to split condensate flow between two units


SSEP0032 to SSEP6621 - Technical Specs

Flow Rates 32 SCFM to 6621 SCFM

Max Capacity (SCFM)
w/out Dryer & Filters*
Max Capacity (SCFM)
with Dryer & Filters*
Connections Dimensions (Inches) Weight
(Lbs)
Unit Model Service Kit**
Condensate Inlet Water Outlet Depth Width Height
32 25 1/4" 3/8" 10 6 9 5.3 SSEP0032N -
66 53 1/4" 3/8" 10 6 9 6.6 SSEP0066N -
32 25 6mm 10mm 10 6 9 5.3 SSEP0032M -
66 53 6mm 10mm 10 6 9 6.6 SSEP0066M -
132 106 2 x 1/2" 1/2" 15 11 17 16.5 SSEP0132 SSEPSK0132
225 180 2 x 1/2" 1/2" 16 11 20 23.8 SSEP0225 SSEPSK0225
450 360 2 x 1/2" 1/2" 19 16 23 38.4 SSEP0450 SSEPSK0450
795 636 2 x 3/4" 3/4" 23 18 28 71.4 SSEP0795 SSEPSK0795
1655 1324 2 x 3/4" 3/4" 27 22 38 123.2 SSEP1655 SSEPSK1655
3311 2648 2 x 3/4" 3/4" 38 31 39 253.5 SSEP3311 SSEPSK3311
6621 5296 2 x 3/4" 3/4" 38 (x2) 31 (x2) 39 (x2) 529.1 SSEP6621 SSEPSK6621

*Rated capacities based upon 12 hour/day operation, 60% relative humidity, ambient temperature of 77°F & system operating pressure of 100 psig
**Service kit includes: condensate inlet system, pre filter system, fine filter, and miscellaneous parts


Correction Factors

Apply correction factors to unit model capacity using the following to find the adjusted model capacity:
     Relative Humidity CF x Ambient Temperature CF x Running Hours CF x Model Capacity = Adjusted Model Capacity

Relative Humidty
(HCF)
% 50 60 70 80 90 - -
Correction Factor 1.1 1 0.85 0.74 0.66 - -
Ambient Temperature
(TCF)
°F 59 68 77 86 95 104 -
Correction Factor 1.33 1.17 1 0.76 0.5 0.3 -
Running Hours Per Day
(RCF)
Hours 12 14 16 18 20 22 24
Correction Factor 1 0.86 0.75 0.67 0.60 0.55 0.50

Example

Operating Env Correction Factor
Relative Humidity 50% HCF = 1.1
Ambient Temperature 86°F TCF = 0.76
Running Hours/Day 24 RCF = .5
Model Capacity 66 MC = 66
Adjusted Model Capacity HCF x TCF x RCF x MC 1.1 x 0.76 x 0.5 x 66
= 27.72 SCFM

Accessories

Wall mounting kit for models SSEP0032 & SSPE0066 SSEPMBK1
Manifold for models SSEP0132 to SSEP0450 SSEPM1
Manifold for models SSEP0795 to SSEP6621 SSEPM2